5 research outputs found

    A Deep Learning Approach Utilizing Covariance Matrix Analysis for the ISBI Edited MRS Reconstruction Challenge

    Get PDF
    This work proposes a method to accelerate the acquisition of high-quality edited magnetic resonance spectroscopy (MRS) scans using machine learning models taking the sample covariance matrix as input. The method is invariant to the number of transients and robust to noisy input data for both synthetic as well as in-vivo scenarios

    A review of machine learning applications for the proton MR spectroscopy workflow

    Get PDF
    This literature review presents a comprehensive overview of machine learning (ML) applications in proton MR spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state-of-the-art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the MR field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.</p

    A comparison of video-based methods for neonatal body motion detection

    Get PDF
    Preterm infants in a neonatal intensive care unit (NICU) are continuously monitored for their vital signs, such as heart rate and oxygen saturation. Body motion patterns are documented intermittently by clinical observations. Changing motion patterns in preterm infants are associated with maturation and clinical events such as late-onset sepsis and seizures. However, continuous motion monitoring in the NICU setting is not yet performed. Video-based motion monitoring is a promising method due to its non-contact nature and therefore unobtrusiveness. This study aims to determine the feasibility of simple video-based methods for infant body motion detection. We investigated and compared four methods to detect the motion in videos of infants, using two datasets acquired with different types of cameras. The thermal dataset contains 32 hours of annotated videos from 13 infants in open beds. The RGB dataset contains 9 hours of annotated videos from 5 infants in incubators. The compared methods include background substruction (BS), sparse optical flow (SOF), dense optical flow (DOF), and oriented FAST and rotated BRIEF (ORB). The detection performance and computation time were evaluated by the area under receiver operating curves (AUC) and run time. We conducted experiments to detect motion and gross motion respectively. In the thermal dataset, the best performance of both experiments is achieved by BS with mean (standard deviation) AUCs of 0.86 (0.03) and 0.93 (0.03). In the RGB dataset, SOF outperforms the other methods in both experiments with AUCs of 0.82 (0.10) and 0.91 (0.05). All methods are efficient to be integrated into a camera system when using low-resolution thermal cameras

    A Review of Machine Learning Applications for the Proton Magnetic Resonance Spectroscopy Workflow

    Get PDF
    This literature review presents a comprehensive overview of machine learning (ML) applications in proton magnetic resonance spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state-of-the-art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the magnetic resonance field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in-vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field

    A randomised, blinded, trial of clopidogrel versus aspirin in patients at risk of ischaemic events (CAPRIE). CAPRIE Steering Committee

    No full text
    Many clinical trials have evaluated the benefit of long-term use of antiplatelet drugs in reducing the risk of clinical thrombotic events. Aspirin and ticlopidine have been shown to be effective, but both have potentially serious adverse effects. Clopidogrel, a new thienopyridine derivative similar to ticlopidine, is an inhibitor of platelet aggregation induced by adenosine diphosphate. METHODS: CAPRIE was a randomised, blinded, international trial designed to assess the relative efficacy of clopidogrel (75 mg once daily) and aspirin (325 mg once daily) in reducing the risk of a composite outcome cluster of ischaemic stroke, myocardial infarction, or vascular death; their relative safety was also assessed. The population studied comprised subgroups of patients with atherosclerotic vascular disease manifested as either recent ischaemic stroke, recent myocardial infarction, or symptomatic peripheral arterial disease. Patients were followed for 1 to 3 years. FINDINGS: 19,185 patients, with more than 6300 in each of the clinical subgroups, were recruited over 3 years, with a mean follow-up of 1.91 years. There were 1960 first events included in the outcome cluster on which an intention-to-treat analysis showed that patients treated with clopidogrel had an annual 5.32% risk of ischaemic stroke, myocardial infarction, or vascular death compared with 5.83% with aspirin. These rates reflect a statistically significant (p = 0.043) relative-risk reduction of 8.7% in favour of clopidogrel (95% Cl 0.3-16.5). Corresponding on-treatment analysis yielded a relative-risk reduction of 9.4%. There were no major differences in terms of safety. Reported adverse experiences in the clopidogrel and aspirin groups judged to be severe included rash (0.26% vs 0.10%), diarrhoea (0.23% vs 0.11%), upper gastrointestinal discomfort (0.97% vs 1.22%), intracranial haemorrhage (0.33% vs 0.47%), and gastrointestinal haemorrhage (0.52% vs 0.72%), respectively. There were ten (0.10%) patients in the clopidogrel group with significant reductions in neutrophils (< 1.2 x 10(9)/L) and 16 (0.17%) in the aspirin group. INTERPRETATION: Long-term administration of clopidogrel to patients with atherosclerotic vascular disease is more effective than aspirin in reducing the combined risk of ischaemic stroke, myocardial infarction, or vascular death. The overall safety profile of clopidogrel is at least as good as that of medium-dose aspirin
    corecore